Package com.merge.HL7.v251.segments

This package provides classes that model the segment types defines by the HL7 standard version 2.5.1.

See:
          Description

Class Summary
HL7SegmentABS This segment was created to communicate patient abstract information used for billing and reimbursement purposes.
HL7SegmentACC The ACC segment contains patient information relative to an accident in which the patient has been involved.
HL7SegmentADD The ADD segment is used to define the continuation of the prior segment in a continuation message.
HL7SegmentAFF The AFF segment adds detailed information regarding professional affiliations with which the staff member identified by the STF segment is/was associated.
HL7SegmentAIG The AIG segment contains information about various kinds of resources (other than those with specifically defined segments in this chapter) that can be scheduled.
HL7SegmentAIL The AIL segment contains information about location resources (meeting rooms, operating rooms, examination rooms, or other locations) that can be scheduled.
HL7SegmentAIP The AIP segment contains information about the personnel types that can be scheduled.
HL7SegmentAIS The AIS segment contains information about various kinds of services that can be scheduled.
HL7SegmentAL1 The AL1 segment contains patient allergy information of various types.
HL7SegmentAPR The APR segment contains parameters and preference specifications used for requesting appointments in the SRM message.
HL7SegmentARQ The ARQ segment defines a request for the booking of an appointment.
HL7SegmentAUT This segment represents an authorization or a pre-authorization for a referred procedure or requested service by the payor covering the patient’s health care.
HL7SegmentBHS The BHS segment defines the start of a batch.
HL7SegmentBLC The BLC segment contains data necessary to communicate patient abstract blood information used for billing and reimbursement purposes.
HL7SegmentBLG The BLG segment is used to provide billing information, on the ordered service, to the filling application.
HL7SegmentBPO Blood product order messages require additional information that is not available in other standard HL7 order messages.
HL7SegmentBPX In the processing of blood products, it is necessary for the transfusion service and the placer system to communicate information.
HL7SegmentBTS The BTS segment defines the end of a batch.
HL7SegmentBTX Blood Product Transfusion/Disposition Segment
HL7SegmentCDM The Technical Steward for the CDM segment is FM.
HL7SegmentCER The CER segment adds detailed information regarding the formal authorizations to provide a service (e.g.
HL7SegmentCM0 The Technical Steward for the CM0 segment is ORDERS.
HL7SegmentCM1 The Technical Steward for the CM1 segment is ORDERS.
HL7SegmentCM2 The Technical Steward for the CM2 segment is ORDERS.
HL7SegmentCNS The clear equipment notification segment contains the data necessary to allow the receiving equipment to clear any associated notifications.
HL7SegmentCON The consent segment provides details about a specific consent by a patient or staff member.
HL7SegmentConstants  
HL7SegmentCSP The CSP segment contains information on a patient’s status for a particular phase of the study.
HL7SegmentCSR The CSR segment will contain fundamental administrative and regulatory information required to document a patient’s enrollment on a clinical trial.
HL7SegmentCSS The Clinical Study Data Schedule (CSS) segment is optional depending on whether messaging of study data needs to be linked to the scheduled data time points for the study.
HL7SegmentCTD The CTD segment may identify any contact personnel associated with a patient referral message and its related transactions.
HL7SegmentCTI The CTI segment is an optional segment that contains information to identify the clinical trial, phase and time point with which an order or result is associated.
HL7SegmentDB1 The disability segment contains information related to the disability of a person.
HL7SegmentDG1 The DG1 segment contains patient diagnosis information of various types, for example, admitting, primary, etc.
HL7SegmentDRG The DRG segment contains diagnoses-related grouping information of various types.
HL7SegmentDSC The DSC segment is used in the continuation protocol.
HL7SegmentDSP The DSP segment is used to contain data that has been preformatted by the sender for display.
HL7SegmentECD The equipment command segment contains the information required to notify the receiving component what is to happen.
HL7SegmentECR The equipment command response segment contains the receiving component's response to the previously received command.
HL7SegmentEDU The EDU segment adds detailed educational information to the staff member identified by the STF segment.
HL7SegmentEQL The EQL segment is used to define queries using select statements based on the query language of choice (e.g., SQL).
HL7SegmentEQP The equipment log/service segment is the data necessary to maintain an adequate audit trail of events that have occurred on a particular piece of equipment.
HL7SegmentEQU The equipment detail segment contains the data necessary to identify and maintain the equipment that is being used throughout the Laboratory Automation System.
HL7SegmentERQ The ERQ segment is used to issue queries where the desired response is formatted as an event replay response message.
HL7SegmentERR The ERR segment is used to add error comments to acknowledgment messages.
HL7SegmentEVN The EVN segment is used to communicate necessary trigger event information to receiving applications.
HL7SegmentFAC 7.12.6 FAC - Facility Segment
HL7SegmentFHS The FHS segment is used to head a file (group of batches) as defined in Section 2.10.3, HL7 batch protocol.
HL7SegmentFT1 The FT1 segment contains the detail data necessary to post charges, payments, adjustments, etc.
HL7SegmentFTS The FTS segment defines the end of a file.
HL7SegmentGOL The goal detail segment contains the data necessary to add, update, correct, and delete the goals for an individual.
HL7SegmentGP1 These fields are used in grouping and reimbursement for CMS APCs.
HL7SegmentGP2 This segment is used for items that pertain to each HCPC/CPT line item.
HL7SegmentGT1 The GT1 segment contains guarantor (e.g., the person or the organization with financial responsibility for payment of a patient account) data for patient and insurance billing applications.
HL7SegmentIAM The IAM segment contains person/patient adverse reaction information of various types.
HL7SegmentIIM The Inventory Item Master segment (IIM) contains information about the stock of product that can be used to fulfill an ordered test/service.
HL7SegmentIN1 The IN1 segment contains insurance policy coverage information necessary to produce properly pro rated and patient and insurance bills.
HL7SegmentIN2 The IN2 segment contains additional insurance policy coverage and benefit information necessary for proper billing and reimbursement.
HL7SegmentIN3 The IN3 segment contains additional insurance information for certifying the need for patient care.
HL7SegmentINV The inventory detail segment is the data necessary to track the inventory of substances (e.g.
HL7SegmentIPC The IPC segment contains information about tasks that need to be performed in order to fulfill the request for imaging service.
HL7SegmentISD The interaction detail segment contains information about the status of specific interaction (e.g., processing — see section Glossary) on the specific equipment.
HL7SegmentLAN The LAN segment adds detailed language information to the staff member identified by the STF segment.
HL7SegmentLCC The Technical Steward for the LCC segment is PA.
HL7SegmentLCH The Technical Steward for the LCH segment is PA.
HL7SegmentLDP The Technical Steward for the LDP segment is PA.
HL7SegmentLOC The LOC segment can identify any patient location referenced by information systems.
HL7SegmentLRL The Technical Steward for the LRL segment is PA.
HL7SegmentMFA The Technical Steward for the MFA segment is CQ.
HL7SegmentMFE The Technical Steward for the MFE segment is CQ.
HL7SegmentMFI The Technical Steward for the MFI segment is CQ.
HL7SegmentMRG The MRG segment provides receiving applications with information necessary to initiate the merging of patient data as well as groups of records.
HL7SegmentMSA The MSA segment contains information sent while acknowledging another message.
HL7SegmentMSH The MSH segment defines the intent, source, destination, and some specifics of the syntax of a message.
HL7SegmentNCK The NCK segment is used to allow the various applications on the network to synchronize their system clocks (system date and time).
HL7SegmentNDS The equipment notification detail segment is the data necessary to maintain an adequate audit trail as well as notifications of events, (e.g., alarms that have occurred on a particular piece of equipment.
HL7SegmentNK1 The NK1 segment contains information about the patient’s other related parties.
HL7SegmentNPU The NPU segment allows the updating of census (bed status) data without sending patient-specific data.
HL7SegmentNSC The NSC segment is used to inform (NMR query response) or announce (NMD unsolicited update) the start up, shut down, and/or migration (to a different cpu or file server/file system) of a particular application.
HL7SegmentNST The NST segment allows application control-level statistical information to be passed between the various systems on the network.
HL7SegmentNTE The NTE segment is defined here for inclusion in messages defined in other chapters.
HL7SegmentOBR General (taken from ASTM E1238) The Observation Request (OBR) segment is used to transmit information specific to an order for a diagnostic study or observation, physical exam, or assessment.
HL7SegmentOBX The OBX segment is used to transmit a single observation or observation fragment.
HL7SegmentODS The ORC sequence items of interest to ODS are ORC-1-order control, ORC-2-placer order number, ORC-3-filler order number, ORC-7-quantity/timing, ORC-9-date/time of transaction, ORC-10-entered by, and ORC-11-verified by.
HL7SegmentODT This segment addresses tray instructions.
HL7SegmentOM1 The Technical Steward for the OM1 segment is ORDERS.
HL7SegmentOM2 The Technical Steward for the OM2 segment is ORDERS.
HL7SegmentOM3 The Technical Steward for the OM3 segment is ORDERS.
HL7SegmentOM4 The Technical Steward for the OM4 segment is ORDERS.
HL7SegmentOM5 The Technical Steward for the OM5 segment is ORDERS.
HL7SegmentOM6 The Technical Steward for the OM6 segment is ORDERS.
HL7SegmentOM7 The OM7 segment contains additional basic attributes that apply to the definition of most observations/services.
HL7SegmentORC The Common Order segment (ORC) is used to transmit fields that are common to all orders (all types of services that are requested).
HL7SegmentORG The ORG segment relates a practitioner to an organization unit and adds detailed information regarding the practitioner's practicing specialty in that organization unit.
HL7SegmentOVR Definition: This segment allows a sender to override specific receiving application’s business rules to allow for processing of a message that would normally be rejected or ignored.
HL7SegmentPCR The PCR segment is used to communicate a potential or suspected relationship between a product (drug or device) or test and an event with detrimental effect on a patient.
HL7SegmentPD1 The patient additional demographic segment contains demographic information that is likely to change about the patient.
HL7SegmentPDA This segment carries information on a patient’s death and possible autopsy.
HL7SegmentPDC 7.12.5 PDC - Product Detail Country Segment
HL7SegmentPEO Details related to a particular clinical experience or event are embodied in the PEO segment.
HL7SegmentPES 7.12.1 PES - Product Experience Sender Segment
HL7SegmentPID The PID segment is used by all applications as the primary means of communicating patient identification information.
HL7SegmentPR1 The PR1 segment contains information relative to various types of procedures that can be performed on a patient.
HL7SegmentPRA The Technical Steward for the PRA segment is PA and Personnel Management.
HL7SegmentPRB The problem detail segment contains the data necessary to add, update, correct, and delete the problems of a given individual.
HL7SegmentPRC The Technical Steward for the PRC segment is PA.
HL7SegmentPRD This segment will be employed as part of a patient referral message and its related transactions.
HL7SegmentPSH 7.12.4 PSH - Product Summary Header Segment
HL7SegmentPTH The pathway segment contains the data necessary to add, update, correct, and delete from the record pathways that are utilized to address an individual’s health care.
HL7SegmentPV1 The PV1 segment is used by Registration/Patient Administration applications to communicate information on an account or visit-specific basis.
HL7SegmentPV2 The PV2 segment is a continuation of information contained on the PV1 segment.
HL7SegmentQAK The QAK segment contains information sent with responses to a query.
HL7SegmentQID The QID segment contains the information necessary to uniquely identify a query.
HL7SegmentQPD The QPD segment defines the parameters of the query.
HL7SegmentQRD The QRD segment is used to define a query.
HL7SegmentQRF The QRF segment is used with the QRD segment to further refine the content of an original style query.
HL7SegmentQRI The QRI segment is used to indicate the weight match for a returned record (where the responding system employs a numeric algorithm) and/or the match reason code (where the responding system uses rules or other match options).
HL7SegmentRCP The RCP segment is used to restrict the amount of data that should be returned in response to query.
HL7SegmentRDF The RDF segment defines the content of the row data segments (RDT) in the tabular response (RTB).
HL7SegmentRDT The RDT segment contains the row data of the tabular data response message (TBR).
HL7SegmentRF1 This segment represents information that may be useful when sending referrals from the referring provider to the referred-to provider.
HL7SegmentRGS The RGS segment is used to identify relationships between resources identified for a scheduled event.
HL7SegmentRMI The RMI segment is used to report an occurrence of an incident event pertaining or attaching to a patient encounter.
HL7SegmentROL The role segment contains the data necessary to add, update, correct, and delete from the record persons involved, as well as their functional involvement with the activity being transmitted.
HL7SegmentRQ1 RQ1 contains additional detail for each nonstock requisitioned item.
HL7SegmentRQD RQD contains the detail for each requisitioned item
HL7SegmentRXA The ORC must have the filler order number and the order control code RE.
HL7SegmentRXC If the drug or treatment ordered with the RXO segment is a compound drug OR an IV solution, AND there is not a coded value for OBR-4-universal service ID, which specifies the components (base and all additives), then the components (the base and additives) are specified by two or more RXC segments.
HL7SegmentRXD Dispense Segment
HL7SegmentRXE The RXE segment details the pharmacy or treatment application's encoding of the order.
HL7SegmentRXG Pharmacy Treatment Give Segment
HL7SegmentRXO This is the "master" pharmacy/treatment order segment.
HL7SegmentRXR The Pharmacy/Treatment Route segment contains the alternative combination of route, site, administration device, and administration method that are prescribed as they apply to a particular order.
HL7SegmentSAC The container detail segment is the data necessary to maintain the containers that are being used throughout the Laboratory Automation System.
HL7SegmentSCH The SCH segment contains general information about the scheduled appointment.
HL7SegmentSFT Definition: This segment provides additional information about the software product(s) used as a Sending Application.
HL7SegmentSID The Substance Identifier segment contains data necessary to identify the substance (e.g., reagents) used in the production of analytical test results.
HL7SegmentSPM The intent of this segment is to describe the characteristics of a specimen.
HL7SegmentSPR The SPR segment is used to issue queries using stored procedure calls.
HL7SegmentSTF The Technical Steward for the STF segment is PA and Personnel Management.
HL7SegmentTCC The test (e.g., analyte) code configuration segment is the data necessary to maintain and transmit information concerning the test entity codes that are being used throughout the"automated system."
HL7SegmentTCD The test code detail segment contains the data necessary to perform operations or calculations, or execute decisions by the laboratory automation system, and which are not supported by the original HL7 segments related to orders (ORC, OBR).
HL7SegmentTQ1 The TQ1 segment is used to specify the complex timing of events and actions such as those that occur in order management and scheduling systems.
HL7SegmentTQ2 The TQ2 segment is used to form a relationship between the service request the TQ1/TQ2 segments are associated with, and other service requests.
HL7SegmentTXA The TXA segment contains information specific to a transcribed document but does not include the text of the document.
HL7SegmentUB1 The UB1 segment contains the data necessary to complete UB82 bills specific to the United States; other realms may choose to implement using regional code sets.
HL7SegmentUB2 The UB2 segment contains data necessary to complete UB92 bills specific to the United States; other realms may choose to implement using regional code sets.
HL7SegmentURD The URD segment is used in sending unsolicited updates about orders and results.
HL7SegmentURS The URS segment is identical with the QRF segment, except that if the name of any field contains Query (of QRY), this word has been changed to Results (see URS-5-R/U other results subject definition).
HL7SegmentVAR The variance segment contains the data necessary to describe differences that may have occurred at the time when a healthcare event was documented.
HL7SegmentVTQ The VTQ segment is used to define queries that are responded to with the Tabular Data Message (TBR).
 

Package com.merge.HL7.v251.segments Description

This package provides classes that model the segment types defines by the HL7 standard version 2.5.1.


Copyright © 2009 Merge Healthcare Inc. All Rights Reserved.